1Generic Thermal Sysfs driver How To
2===================================
3
4Written by Sujith Thomas <sujith.thomas@intel.com>, Zhang Rui <rui.zhang@intel.com>
5
6Updated: 2 January 2008
7
8Copyright (c)  2008 Intel Corporation
9
10
110. Introduction
12
13The generic thermal sysfs provides a set of interfaces for thermal zone
14devices (sensors) and thermal cooling devices (fan, processor...) to register
15with the thermal management solution and to be a part of it.
16
17This how-to focuses on enabling new thermal zone and cooling devices to
18participate in thermal management.
19This solution is platform independent and any type of thermal zone devices
20and cooling devices should be able to make use of the infrastructure.
21
22The main task of the thermal sysfs driver is to expose thermal zone attributes
23as well as cooling device attributes to the user space.
24An intelligent thermal management application can make decisions based on
25inputs from thermal zone attributes (the current temperature and trip point
26temperature) and throttle appropriate devices.
27
28[0-*]	denotes any positive number starting from 0
29[1-*]	denotes any positive number starting from 1
30
311. thermal sysfs driver interface functions
32
331.1 thermal zone device interface
341.1.1 struct thermal_zone_device *thermal_zone_device_register(char *type,
35		int trips, int mask, void *devdata,
36		struct thermal_zone_device_ops *ops,
37		const struct thermal_zone_params *tzp,
38		int passive_delay, int polling_delay))
39
40    This interface function adds a new thermal zone device (sensor) to
41    /sys/class/thermal folder as thermal_zone[0-*]. It tries to bind all the
42    thermal cooling devices registered at the same time.
43
44    type: the thermal zone type.
45    trips: the total number of trip points this thermal zone supports.
46    mask: Bit string: If 'n'th bit is set, then trip point 'n' is writeable.
47    devdata: device private data
48    ops: thermal zone device call-backs.
49	.bind: bind the thermal zone device with a thermal cooling device.
50	.unbind: unbind the thermal zone device with a thermal cooling device.
51	.get_temp: get the current temperature of the thermal zone.
52	.get_mode: get the current mode (enabled/disabled) of the thermal zone.
53	    - "enabled" means the kernel thermal management is enabled.
54	    - "disabled" will prevent kernel thermal driver action upon trip points
55	      so that user applications can take charge of thermal management.
56	.set_mode: set the mode (enabled/disabled) of the thermal zone.
57	.get_trip_type: get the type of certain trip point.
58	.get_trip_temp: get the temperature above which the certain trip point
59			will be fired.
60	.set_emul_temp: set the emulation temperature which helps in debugging
61			different threshold temperature points.
62    tzp: thermal zone platform parameters.
63    passive_delay: number of milliseconds to wait between polls when
64	performing passive cooling.
65    polling_delay: number of milliseconds to wait between polls when checking
66	whether trip points have been crossed (0 for interrupt driven systems).
67
68
691.1.2 void thermal_zone_device_unregister(struct thermal_zone_device *tz)
70
71    This interface function removes the thermal zone device.
72    It deletes the corresponding entry form /sys/class/thermal folder and
73    unbind all the thermal cooling devices it uses.
74
751.2 thermal cooling device interface
761.2.1 struct thermal_cooling_device *thermal_cooling_device_register(char *name,
77		void *devdata, struct thermal_cooling_device_ops *)
78
79    This interface function adds a new thermal cooling device (fan/processor/...)
80    to /sys/class/thermal/ folder as cooling_device[0-*]. It tries to bind itself
81    to all the thermal zone devices register at the same time.
82    name: the cooling device name.
83    devdata: device private data.
84    ops: thermal cooling devices call-backs.
85	.get_max_state: get the Maximum throttle state of the cooling device.
86	.get_cur_state: get the Current throttle state of the cooling device.
87	.set_cur_state: set the Current throttle state of the cooling device.
88
891.2.2 void thermal_cooling_device_unregister(struct thermal_cooling_device *cdev)
90
91    This interface function remove the thermal cooling device.
92    It deletes the corresponding entry form /sys/class/thermal folder and
93    unbind itself from all the thermal zone devices using it.
94
951.3 interface for binding a thermal zone device with a thermal cooling device
961.3.1 int thermal_zone_bind_cooling_device(struct thermal_zone_device *tz,
97	int trip, struct thermal_cooling_device *cdev,
98	unsigned long upper, unsigned long lower);
99
100    This interface function bind a thermal cooling device to the certain trip
101    point of a thermal zone device.
102    This function is usually called in the thermal zone device .bind callback.
103    tz: the thermal zone device
104    cdev: thermal cooling device
105    trip: indicates which trip point the cooling devices is associated with
106	  in this thermal zone.
107    upper:the Maximum cooling state for this trip point.
108          THERMAL_NO_LIMIT means no upper limit,
109	  and the cooling device can be in max_state.
110    lower:the Minimum cooling state can be used for this trip point.
111          THERMAL_NO_LIMIT means no lower limit,
112	  and the cooling device can be in cooling state 0.
113
1141.3.2 int thermal_zone_unbind_cooling_device(struct thermal_zone_device *tz,
115		int trip, struct thermal_cooling_device *cdev);
116
117    This interface function unbind a thermal cooling device from the certain
118    trip point of a thermal zone device. This function is usually called in
119    the thermal zone device .unbind callback.
120    tz: the thermal zone device
121    cdev: thermal cooling device
122    trip: indicates which trip point the cooling devices is associated with
123	  in this thermal zone.
124
1251.4 Thermal Zone Parameters
1261.4.1 struct thermal_bind_params
127    This structure defines the following parameters that are used to bind
128    a zone with a cooling device for a particular trip point.
129    .cdev: The cooling device pointer
130    .weight: The 'influence' of a particular cooling device on this zone.
131             This is on a percentage scale. The sum of all these weights
132             (for a particular zone) cannot exceed 100.
133    .trip_mask:This is a bit mask that gives the binding relation between
134               this thermal zone and cdev, for a particular trip point.
135               If nth bit is set, then the cdev and thermal zone are bound
136               for trip point n.
137    .limits: This is an array of cooling state limits. Must have exactly
138         2 * thermal_zone.number_of_trip_points. It is an array consisting
139         of tuples <lower-state upper-state> of state limits. Each trip
140         will be associated with one state limit tuple when binding.
141         A NULL pointer means <THERMAL_NO_LIMITS THERMAL_NO_LIMITS>
142         on all trips. These limits are used when binding a cdev to a
143         trip point.
144    .match: This call back returns success(0) if the 'tz and cdev' need to
145	    be bound, as per platform data.
1461.4.2 struct thermal_zone_params
147    This structure defines the platform level parameters for a thermal zone.
148    This data, for each thermal zone should come from the platform layer.
149    This is an optional feature where some platforms can choose not to
150    provide this data.
151    .governor_name: Name of the thermal governor used for this zone
152    .no_hwmon: a boolean to indicate if the thermal to hwmon sysfs interface
153               is required. when no_hwmon == false, a hwmon sysfs interface
154               will be created. when no_hwmon == true, nothing will be done.
155               In case the thermal_zone_params is NULL, the hwmon interface
156               will be created (for backward compatibility).
157    .num_tbps: Number of thermal_bind_params entries for this zone
158    .tbp: thermal_bind_params entries
159
1602. sysfs attributes structure
161
162RO	read only value
163RW	read/write value
164
165Thermal sysfs attributes will be represented under /sys/class/thermal.
166Hwmon sysfs I/F extension is also available under /sys/class/hwmon
167if hwmon is compiled in or built as a module.
168
169Thermal zone device sys I/F, created once it's registered:
170/sys/class/thermal/thermal_zone[0-*]:
171    |---type:			Type of the thermal zone
172    |---temp:			Current temperature
173    |---mode:			Working mode of the thermal zone
174    |---policy:			Thermal governor used for this zone
175    |---trip_point_[0-*]_temp:	Trip point temperature
176    |---trip_point_[0-*]_type:	Trip point type
177    |---trip_point_[0-*]_hyst:	Hysteresis value for this trip point
178    |---emul_temp:		Emulated temperature set node
179
180Thermal cooling device sys I/F, created once it's registered:
181/sys/class/thermal/cooling_device[0-*]:
182    |---type:			Type of the cooling device(processor/fan/...)
183    |---max_state:		Maximum cooling state of the cooling device
184    |---cur_state:		Current cooling state of the cooling device
185
186
187Then next two dynamic attributes are created/removed in pairs. They represent
188the relationship between a thermal zone and its associated cooling device.
189They are created/removed for each successful execution of
190thermal_zone_bind_cooling_device/thermal_zone_unbind_cooling_device.
191
192/sys/class/thermal/thermal_zone[0-*]:
193    |---cdev[0-*]:		[0-*]th cooling device in current thermal zone
194    |---cdev[0-*]_trip_point:	Trip point that cdev[0-*] is associated with
195
196Besides the thermal zone device sysfs I/F and cooling device sysfs I/F,
197the generic thermal driver also creates a hwmon sysfs I/F for each _type_
198of thermal zone device. E.g. the generic thermal driver registers one hwmon
199class device and build the associated hwmon sysfs I/F for all the registered
200ACPI thermal zones.
201
202/sys/class/hwmon/hwmon[0-*]:
203    |---name:			The type of the thermal zone devices
204    |---temp[1-*]_input:	The current temperature of thermal zone [1-*]
205    |---temp[1-*]_critical:	The critical trip point of thermal zone [1-*]
206
207Please read Documentation/hwmon/sysfs-interface for additional information.
208
209***************************
210* Thermal zone attributes *
211***************************
212
213type
214	Strings which represent the thermal zone type.
215	This is given by thermal zone driver as part of registration.
216	E.g: "acpitz" indicates it's an ACPI thermal device.
217	In order to keep it consistent with hwmon sys attribute; this should
218	be a short, lowercase string, not containing spaces nor dashes.
219	RO, Required
220
221temp
222	Current temperature as reported by thermal zone (sensor).
223	Unit: millidegree Celsius
224	RO, Required
225
226mode
227	One of the predefined values in [enabled, disabled].
228	This file gives information about the algorithm that is currently
229	managing the thermal zone. It can be either default kernel based
230	algorithm or user space application.
231	enabled		= enable Kernel Thermal management.
232	disabled	= Preventing kernel thermal zone driver actions upon
233			  trip points so that user application can take full
234			  charge of the thermal management.
235	RW, Optional
236
237policy
238	One of the various thermal governors used for a particular zone.
239	RW, Required
240
241trip_point_[0-*]_temp
242	The temperature above which trip point will be fired.
243	Unit: millidegree Celsius
244	RO, Optional
245
246trip_point_[0-*]_type
247	Strings which indicate the type of the trip point.
248	E.g. it can be one of critical, hot, passive, active[0-*] for ACPI
249	thermal zone.
250	RO, Optional
251
252trip_point_[0-*]_hyst
253	The hysteresis value for a trip point, represented as an integer
254	Unit: Celsius
255	RW, Optional
256
257cdev[0-*]
258	Sysfs link to the thermal cooling device node where the sys I/F
259	for cooling device throttling control represents.
260	RO, Optional
261
262cdev[0-*]_trip_point
263	The trip point with which cdev[0-*] is associated in this thermal
264	zone; -1 means the cooling device is not associated with any trip
265	point.
266	RO, Optional
267
268passive
269	Attribute is only present for zones in which the passive cooling
270	policy is not supported by native thermal driver. Default is zero
271	and can be set to a temperature (in millidegrees) to enable a
272	passive trip point for the zone. Activation is done by polling with
273	an interval of 1 second.
274	Unit: millidegrees Celsius
275	Valid values: 0 (disabled) or greater than 1000
276	RW, Optional
277
278emul_temp
279	Interface to set the emulated temperature method in thermal zone
280	(sensor). After setting this temperature, the thermal zone may pass
281	this temperature to platform emulation function if registered or
282	cache it locally. This is useful in debugging different temperature
283	threshold and its associated cooling action. This is write only node
284	and writing 0 on this node should disable emulation.
285	Unit: millidegree Celsius
286	WO, Optional
287
288	  WARNING: Be careful while enabling this option on production systems,
289	  because userland can easily disable the thermal policy by simply
290	  flooding this sysfs node with low temperature values.
291
292*****************************
293* Cooling device attributes *
294*****************************
295
296type
297	String which represents the type of device, e.g:
298	- for generic ACPI: should be "Fan", "Processor" or "LCD"
299	- for memory controller device on intel_menlow platform:
300	  should be "Memory controller".
301	RO, Required
302
303max_state
304	The maximum permissible cooling state of this cooling device.
305	RO, Required
306
307cur_state
308	The current cooling state of this cooling device.
309	The value can any integer numbers between 0 and max_state:
310	- cur_state == 0 means no cooling
311	- cur_state == max_state means the maximum cooling.
312	RW, Required
313
3143. A simple implementation
315
316ACPI thermal zone may support multiple trip points like critical, hot,
317passive, active. If an ACPI thermal zone supports critical, passive,
318active[0] and active[1] at the same time, it may register itself as a
319thermal_zone_device (thermal_zone1) with 4 trip points in all.
320It has one processor and one fan, which are both registered as
321thermal_cooling_device.
322
323If the processor is listed in _PSL method, and the fan is listed in _AL0
324method, the sys I/F structure will be built like this:
325
326/sys/class/thermal:
327
328|thermal_zone1:
329    |---type:			acpitz
330    |---temp:			37000
331    |---mode:			enabled
332    |---policy:			step_wise
333    |---trip_point_0_temp:	100000
334    |---trip_point_0_type:	critical
335    |---trip_point_1_temp:	80000
336    |---trip_point_1_type:	passive
337    |---trip_point_2_temp:	70000
338    |---trip_point_2_type:	active0
339    |---trip_point_3_temp:	60000
340    |---trip_point_3_type:	active1
341    |---cdev0:			--->/sys/class/thermal/cooling_device0
342    |---cdev0_trip_point:	1	/* cdev0 can be used for passive */
343    |---cdev1:			--->/sys/class/thermal/cooling_device3
344    |---cdev1_trip_point:	2	/* cdev1 can be used for active[0]*/
345
346|cooling_device0:
347    |---type:			Processor
348    |---max_state:		8
349    |---cur_state:		0
350
351|cooling_device3:
352    |---type:			Fan
353    |---max_state:		2
354    |---cur_state:		0
355
356/sys/class/hwmon:
357
358|hwmon0:
359    |---name:			acpitz
360    |---temp1_input:		37000
361    |---temp1_crit:		100000
362
3634. Event Notification
364
365The framework includes a simple notification mechanism, in the form of a
366netlink event. Netlink socket initialization is done during the _init_
367of the framework. Drivers which intend to use the notification mechanism
368just need to call thermal_generate_netlink_event() with two arguments viz
369(originator, event). The originator is a pointer to struct thermal_zone_device
370from where the event has been originated. An integer which represents the
371thermal zone device will be used in the message to identify the zone. The
372event will be one of:{THERMAL_AUX0, THERMAL_AUX1, THERMAL_CRITICAL,
373THERMAL_DEV_FAULT}. Notification can be sent when the current temperature
374crosses any of the configured thresholds.
375
3765. Export Symbol APIs:
377
3785.1: get_tz_trend:
379This function returns the trend of a thermal zone, i.e the rate of change
380of temperature of the thermal zone. Ideally, the thermal sensor drivers
381are supposed to implement the callback. If they don't, the thermal
382framework calculated the trend by comparing the previous and the current
383temperature values.
384
3855.2:get_thermal_instance:
386This function returns the thermal_instance corresponding to a given
387{thermal_zone, cooling_device, trip_point} combination. Returns NULL
388if such an instance does not exist.
389
3905.3:thermal_notify_framework:
391This function handles the trip events from sensor drivers. It starts
392throttling the cooling devices according to the policy configured.
393For CRITICAL and HOT trip points, this notifies the respective drivers,
394and does actual throttling for other trip points i.e ACTIVE and PASSIVE.
395The throttling policy is based on the configured platform data; if no
396platform data is provided, this uses the step_wise throttling policy.
397
3985.4:thermal_cdev_update:
399This function serves as an arbitrator to set the state of a cooling
400device. It sets the cooling device to the deepest cooling state if
401possible.
402