1Davicom DM9000 Fast Ethernet controller
2
3Required properties:
4- compatible = "davicom,dm9000";
5- reg : physical addresses and sizes of registers, must contain 2 entries:
6    first entry : address register,
7    second entry : data register.
8- interrupt-parent : interrupt controller to which the device is connected
9- interrupts : interrupt specifier specific to interrupt controller
10
11Optional properties:
12- davicom,no-eeprom : Configuration EEPROM is not available
13- davicom,ext-phy : Use external PHY
14- reset-gpios : phandle of gpio that will be used to reset chip during probe
15- vcc-supply : phandle of regulator that will be used to enable power to chip
16
17Example:
18
19	ethernet@18000000 {
20		compatible = "davicom,dm9000";
21		reg = <0x18000000 0x2 0x18000004 0x2>;
22		interrupt-parent = <&gpn>;
23		interrupts = <7 4>;
24		local-mac-address = [00 00 de ad be ef];
25		davicom,no-eeprom;
26		reset-gpios = <&gpf 12 GPIO_ACTIVE_LOW>;
27		vcc-supply = <&eth0_power>;
28	};
29