1* Marvell MMP2 Clock Controller 2 3The MMP2 clock subsystem generates and supplies clock to various 4controllers within the MMP2 SoC. 5 6Required Properties: 7 8- compatible: should be one of the following. 9 - "marvell,mmp2-clock" - controller compatible with MMP2 SoC. 10 11- reg: physical base address of the clock subsystem and length of memory mapped 12 region. There are 3 places in SOC has clock control logic: 13 "mpmu", "apmu", "apbc". So three reg spaces need to be defined. 14 15- #clock-cells: should be 1. 16- #reset-cells: should be 1. 17 18Each clock is assigned an identifier and client nodes use this identifier 19to specify the clock which they consume. 20 21All these identifier could be found in <dt-bindings/clock/marvell-mmp2.h>. 22