1What: /sys/class/power/ds2760-battery.*/charge_now 2Date: May 2010 3KernelVersion: 2.6.35 4Contact: Daniel Mack <daniel@caiaq.de> 5Description: 6 This file is writeable and can be used to set the current 7 coloumb counter value inside the battery monitor chip. This 8 is needed for unavoidable corrections of aging batteries. 9 A userspace daemon can monitor the battery charging logic 10 and once the counter drops out of considerable bounds, take 11 appropriate action. 12 13What: /sys/class/power/ds2760-battery.*/charge_full 14Date: May 2010 15KernelVersion: 2.6.35 16Contact: Daniel Mack <daniel@caiaq.de> 17Description: 18 This file is writeable and can be used to set the assumed 19 battery 'full level'. As batteries age, this value has to be 20 amended over time. 21 22What: /sys/class/power_supply/max14577-charger/device/fast_charge_timer 23Date: October 2014 24KernelVersion: 3.18.0 25Contact: Krzysztof Kozlowski <k.kozlowski@samsung.com> 26Description: 27 This entry shows and sets the maximum time the max14577 28 charger operates in fast-charge mode. When the timer expires 29 the device will terminate fast-charge mode (charging current 30 will drop to 0 A) and will trigger interrupt. 31 32 Valid values: 33 - 5, 6 or 7 (hours), 34 - 0: disabled. 35 36What: /sys/class/power_supply/max77693-charger/device/fast_charge_timer 37Date: January 2015 38KernelVersion: 3.19.0 39Contact: Krzysztof Kozlowski <k.kozlowski@samsung.com> 40Description: 41 This entry shows and sets the maximum time the max77693 42 charger operates in fast-charge mode. When the timer expires 43 the device will terminate fast-charge mode (charging current 44 will drop to 0 A) and will trigger interrupt. 45 46 Valid values: 47 - 4 - 16 (hours), step by 2 (rounded down) 48 - 0: disabled. 49 50What: /sys/class/power_supply/max77693-charger/device/top_off_threshold_current 51Date: January 2015 52KernelVersion: 3.19.0 53Contact: Krzysztof Kozlowski <k.kozlowski@samsung.com> 54Description: 55 This entry shows and sets the charging current threshold for 56 entering top-off charging mode. When charging current in fast 57 charge mode drops below this value, the charger will trigger 58 interrupt and start top-off charging mode. 59 60 Valid values: 61 - 100000 - 200000 (microamps), step by 25000 (rounded down) 62 - 200000 - 350000 (microamps), step by 50000 (rounded down) 63 - 0: disabled. 64 65What: /sys/class/power_supply/max77693-charger/device/top_off_timer 66Date: January 2015 67KernelVersion: 3.19.0 68Contact: Krzysztof Kozlowski <k.kozlowski@samsung.com> 69Description: 70 This entry shows and sets the maximum time the max77693 71 charger operates in top-off charge mode. When the timer expires 72 the device will terminate top-off charge mode (charging current 73 will drop to 0 A) and will trigger interrupt. 74 75 Valid values: 76 - 0 - 70 (minutes), step by 10 (rounded down) 77