1Kernel driver sht15 2=================== 3 4Authors: 5 * Wouter Horre 6 * Jonathan Cameron 7 * Vivien Didelot <vivien.didelot@savoirfairelinux.com> 8 * Jerome Oufella <jerome.oufella@savoirfairelinux.com> 9 10Supported chips: 11 * Sensirion SHT10 12 Prefix: 'sht10' 13 14 * Sensirion SHT11 15 Prefix: 'sht11' 16 17 * Sensirion SHT15 18 Prefix: 'sht15' 19 20 * Sensirion SHT71 21 Prefix: 'sht71' 22 23 * Sensirion SHT75 24 Prefix: 'sht75' 25 26Datasheet: Publicly available at the Sensirion website 27http://www.sensirion.ch/en/pdf/product_information/Datasheet-humidity-sensor-SHT1x.pdf 28 29Description 30----------- 31 32The SHT10, SHT11, SHT15, SHT71, and SHT75 are humidity and temperature 33sensors. 34 35The devices communicate using two GPIO lines. 36 37Supported resolutions for the measurements are 14 bits for temperature and 12 38bits for humidity, or 12 bits for temperature and 8 bits for humidity. 39 40The humidity calibration coefficients are programmed into an OTP memory on the 41chip. These coefficients are used to internally calibrate the signals from the 42sensors. Disabling the reload of those coefficients allows saving 10ms for each 43measurement and decrease power consumption, while losing on precision. 44 45Some options may be set directly in the sht15_platform_data structure 46or via sysfs attributes. 47 48Notes: 49 * The regulator supply name is set to "vcc". 50 * If a CRC validation fails, a soft reset command is sent, which resets 51 status register to its hardware default value, but the driver will try to 52 restore the previous device configuration. 53 54Platform data 55------------- 56 57* checksum: 58 set it to true to enable CRC validation of the readings (default to false). 59* no_otp_reload: 60 flag to indicate not to reload from OTP (default to false). 61* low_resolution: 62 flag to indicate the temp/humidity resolution to use (default to false). 63 64Sysfs interface 65--------------- 66 67* temp1_input: temperature input 68* humidity1_input: humidity input 69* heater_enable: write 1 in this attribute to enable the on-chip heater, 70 0 to disable it. Be careful not to enable the heater 71 for too long. 72* temp1_fault: if 1, this means that the voltage is low (below 2.47V) and 73 measurement may be invalid. 74* humidity1_fault: same as temp1_fault. 75