1* Samsung S5P6442/S5PC110/S5PV210 Clock Controller 2 3Samsung S5P6442, S5PC110 and S5PV210 SoCs contain integrated clock 4controller, which generates and supplies clock to various controllers 5within the SoC. 6 7Required Properties: 8 9- compatible: should be one of following: 10 - "samsung,s5pv210-clock" : for clock controller of Samsung 11 S5PC110/S5PV210 SoCs, 12 - "samsung,s5p6442-clock" : for clock controller of Samsung 13 S5P6442 SoC. 14 15- reg: physical base address of the controller and length of memory mapped 16 region. 17 18- #clock-cells: should be 1. 19 20All available clocks are defined as preprocessor macros in 21dt-bindings/clock/s5pv210.h header and can be used in device tree sources. 22 23External clocks: 24 25There are several clocks that are generated outside the SoC. It is expected 26that they are defined using standard clock bindings with following 27clock-output-names: 28 - "xxti": external crystal oscillator connected to XXTI and XXTO pins of 29the SoC, 30 - "xusbxti": external crystal oscillator connected to XUSBXTI and XUSBXTO 31pins of the SoC, 32 33A subset of above clocks available on given board shall be specified in 34board device tree, including the system base clock, as selected by XOM[0] 35pin of the SoC. Refer to generic fixed rate clock bindings 36documentation[1] for more information how to specify these clocks. 37 38[1] Documentation/devicetree/bindings/clock/fixed-clock.txt 39 40Example: Clock controller node: 41 42 clock: clock-controller@7e00f000 { 43 compatible = "samsung,s5pv210-clock"; 44 reg = <0x7e00f000 0x1000>; 45 #clock-cells = <1>; 46 }; 47 48Example: Required external clocks: 49 50 xxti: clock-xxti { 51 compatible = "fixed-clock"; 52 clock-output-names = "xxti"; 53 clock-frequency = <24000000>; 54 #clock-cells = <0>; 55 }; 56 57 xusbxti: clock-xusbxti { 58 compatible = "fixed-clock"; 59 clock-output-names = "xusbxti"; 60 clock-frequency = <24000000>; 61 #clock-cells = <0>; 62 }; 63 64Example: UART controller node that consumes the clock generated by the clock 65 controller (refer to the standard clock bindings for information about 66 "clocks" and "clock-names" properties): 67 68 uart0: serial@e2900000 { 69 compatible = "samsung,s5pv210-uart"; 70 reg = <0xe2900000 0x400>; 71 interrupt-parent = <&vic1>; 72 interrupts = <10>; 73 clock-names = "uart", "clk_uart_baud0", 74 "clk_uart_baud1"; 75 clocks = <&clocks UART0>, <&clocks UART0>, 76 <&clocks SCLK_UART0>; 77 status = "disabled"; 78 }; 79