Searched refs:cache_events (Results 1 – 22 of 22) sorted by relevance
/linux-4.4.14/arch/powerpc/include/asm/ |
D | perf_event_fsl_emb.h | 45 int (*cache_events)[PERF_COUNT_HW_CACHE_MAX] member
|
D | perf_event_server.h | 49 int (*cache_events)[PERF_COUNT_HW_CACHE_MAX] member
|
/linux-4.4.14/arch/sh/include/asm/ |
D | perf_event.h | 19 const int (*cache_events)[PERF_COUNT_HW_CACHE_MAX] member
|
/linux-4.4.14/arch/metag/kernel/perf/ |
D | perf_event.h | 86 const int (*cache_events)[PERF_COUNT_HW_CACHE_MAX] member
|
D | perf_event.c | 519 if (!metag_pmu->cache_events) in _hw_perf_cache_event() 532 ev = (*metag_pmu->cache_events)[type][op][result]; in _hw_perf_cache_event() 800 .cache_events = &metag_pmu_cache_events,
|
/linux-4.4.14/arch/powerpc/perf/ |
D | e6500-pmu.c | 109 .cache_events = &e6500_cache_events,
|
D | e500-pmu.c | 120 .cache_events = &e500_cache_events,
|
D | core-fsl-emb.c | 464 if (!ppmu->cache_events) in hw_perf_cache_event() 477 ev = (*ppmu->cache_events)[type][op][result]; in hw_perf_cache_event()
|
D | mpc7450-pmu.c | 411 .cache_events = &mpc7450_cache_events,
|
D | ppc970-pmu.c | 489 .cache_events = &ppc970_cache_events,
|
D | power6-pmu.c | 540 .cache_events = &power6_cache_events,
|
D | power7-pmu.c | 444 .cache_events = &power7_cache_events,
|
D | power4-pmu.c | 609 .cache_events = &power4_cache_events,
|
D | power5-pmu.c | 617 .cache_events = &power5_cache_events,
|
D | power5+-pmu.c | 677 .cache_events = &power5p_cache_events,
|
D | power8-pmu.c | 822 .cache_events = &power8_cache_events,
|
D | core-book3s.c | 1742 if (!ppmu->cache_events) in hw_perf_cache_event() 1755 ev = (*ppmu->cache_events)[type][op][result]; in hw_perf_cache_event()
|
/linux-4.4.14/arch/sh/kernel/ |
D | perf_event.c | 99 if (!sh_pmu->cache_events) in hw_perf_cache_event() 112 ev = (*sh_pmu->cache_events)[type][op][result]; in hw_perf_cache_event()
|
/linux-4.4.14/arch/tile/kernel/ |
D | perf_event.c | 66 const int (*cache_events)[PERF_COUNT_HW_CACHE_MAX] member 334 .cache_events = &tile_cache_event_map, 760 if (!tile_pmu->cache_events) in tile_map_cache_event() 775 code = (*tile_pmu->cache_events)[cache_type][cache_op][cache_result]; in tile_map_cache_event()
|
/linux-4.4.14/arch/blackfin/kernel/ |
D | perf_event.c | 83 static const int cache_events[PERF_COUNT_HW_CACHE_MAX] variable 251 ev = cache_events[type][op][result]; in hw_perf_cache_event()
|
/linux-4.4.14/arch/sh/kernel/cpu/sh4a/ |
D | perf_event.c | 282 .cache_events = &sh4a_cache_events,
|
/linux-4.4.14/arch/sh/kernel/cpu/sh4/ |
D | perf_event.c | 248 .cache_events = &sh7750_cache_events,
|