Lines Matching refs:CS8900

14 CIRRUS LOGIC LAN CS8900/CS8920 ETHERNET ADAPTERS
21 1.0 CIRRUS LOGIC LAN CS8900/CS8920 ETHERNET ADAPTERS
30 2.1 CS8900-based Adapter Configuration
56 1.0 CIRRUS LOGIC LAN CS8900/CS8920 ETHERNET ADAPTERS
62 The CS8900-based ISA Ethernet Adapters from Cirrus Logic follow
69 CS8920-based adapters are similar to the CS8900-based adapter with additional
78 The CS8900/CS8920 Ethernet Adapter driver for Linux supports the Linux
103 * Cirrus Logic LAN (CS8900/20-based) Ethernet ISA Adapter
108 * One available IRQ (5,10,11,or 12 for the CS8900, 3-7,9-15 for CS8920).
117 * CS8900/20 Setup Utility (DOS-based)
145 Both the CS8900 and CS8920-based adapters can be configured using parameters
146 stored in an on-board EEPROM. You must use the DOS-based CS8900/20 Setup
154 Since the CS8900/20 Setup Utility is a DOS-based application, you must install
155 and configure the adapter in a DOS-based system using the CS8900/20 Setup
157 installing a CS8900-based adapter and the default configuration is acceptable.)
160 2.1 CS8900-BASED ADAPTER CONFIGURATION
162 CS8900-based adapters shipped from Cirrus Logic have been configured
177 CS8900/20 Setup Utility.
185 run the CS8900/20 Setup Utility to disable PnP and configure the
196 * RUN THE CS8900/20 SETUP UTILITY TO DISABLE PnP SUPPORT AND *
272 * CS8900 defaults to half-duplex if not specified on command-line
379 the CS8900/20 Setup Utility can be used to test the functionality of the
384 CS8900/20-based adapter card (it must also be running the CS8900/20 Setup
392 To run the diagnostics tests on the CS8900/20 adapter:
394 1.) Boot DOS on the PC and start the CS8900/20 Setup Utility.
411 The IO Register Read/Write test insures that the CS8900/20 can be
415 The Shared Memory test insures the CS8900/20 can be accessed in memory
427 The Chip RAM test insures the 4K of memory internal to the CS8900/20 is
452 transferring data between two CS8900/20 adapters installed in different PCs
456 This test requires that each of the two PCs have a CS8900/20-based adapter
457 installed and have the CS8900/20 Setup Utility running. The first PC is
469 1.) Select a PC with a CS8900/20-based adapter and a known working network
470 connection to act as the Responder. Run the CS8900/20 Setup Utility
474 2.) Return to the PC with the CS8900/20-based adapter you want to test and
475 start the CS8900/20 Setup Utility.
504 of four ways after installing and or configuring the CS8900/20-based adapter:
517 If an IO conflict occurs, run the CS8900/20 Setup Utility and perform a
525 CS8900/20 Setup Utility. Once reinstalled in the target system, run the