Lines Matching refs:e_dbg

142 		e_dbg("PHY Address %d is out of range\n", offset);  in e1000e_read_phy_reg_mdic()
167 e_dbg("MDI Read did not complete\n"); in e1000e_read_phy_reg_mdic()
171 e_dbg("MDI Error\n"); in e1000e_read_phy_reg_mdic()
175 e_dbg("MDI Read offset error - requested %d, returned %d\n", in e1000e_read_phy_reg_mdic()
205 e_dbg("PHY Address %d is out of range\n", offset); in e1000e_write_phy_reg_mdic()
231 e_dbg("MDI Write did not complete\n"); in e1000e_write_phy_reg_mdic()
235 e_dbg("MDI Error\n"); in e1000e_write_phy_reg_mdic()
239 e_dbg("MDI Write offset error - requested %d, returned %d\n", in e1000e_write_phy_reg_mdic()
316 e_dbg("Setting page 0x%x\n", page); in e1000_set_page_igp()
758 e_dbg("Error committing the PHY changes\n"); in e1000e_copper_link_setup_m88()
814 e_dbg("Error committing the PHY changes\n"); in e1000e_copper_link_setup_m88()
850 e_dbg("Error resetting the PHY.\n"); in e1000e_copper_link_setup_igp()
863 e_dbg("Error Disabling LPLU D0\n"); in e1000e_copper_link_setup_igp()
972 e_dbg("autoneg_advertised %x\n", phy->autoneg_advertised); in e1000_phy_setup_autoneg()
976 e_dbg("Advertise 10mb Half duplex\n"); in e1000_phy_setup_autoneg()
982 e_dbg("Advertise 10mb Full duplex\n"); in e1000_phy_setup_autoneg()
988 e_dbg("Advertise 100mb Half duplex\n"); in e1000_phy_setup_autoneg()
994 e_dbg("Advertise 100mb Full duplex\n"); in e1000_phy_setup_autoneg()
1000 e_dbg("Advertise 1000mb Half duplex request denied!\n"); in e1000_phy_setup_autoneg()
1004 e_dbg("Advertise 1000mb Full duplex\n"); in e1000_phy_setup_autoneg()
1061 e_dbg("Flow control param set incorrectly\n"); in e1000_phy_setup_autoneg()
1069 e_dbg("Auto-Neg Advertising %x\n", mii_autoneg_adv_reg); in e1000_phy_setup_autoneg()
1103 e_dbg("Reconfiguring auto-neg advertisement params\n"); in e1000_copper_link_autoneg()
1106 e_dbg("Error Setting up Auto-Negotiation\n"); in e1000_copper_link_autoneg()
1109 e_dbg("Restarting Auto-Neg\n"); in e1000_copper_link_autoneg()
1129 e_dbg("Error while waiting for autoneg to complete\n"); in e1000_copper_link_autoneg()
1164 e_dbg("Forcing Speed and Duplex\n"); in e1000e_setup_copper_link()
1167 e_dbg("Error Forcing Speed and Duplex\n"); in e1000e_setup_copper_link()
1181 e_dbg("Valid link established!!!\n"); in e1000e_setup_copper_link()
1185 e_dbg("Unable to establish link!!!\n"); in e1000e_setup_copper_link()
1230 e_dbg("IGP PSCR: %X\n", phy_data); in e1000e_phy_force_speed_duplex_igp()
1235 e_dbg("Waiting for forced speed/duplex link on IGP phy.\n"); in e1000e_phy_force_speed_duplex_igp()
1243 e_dbg("Link taking longer than expected.\n"); in e1000e_phy_force_speed_duplex_igp()
1282 e_dbg("M88E1000 PSCR: %X\n", phy_data); in e1000e_phy_force_speed_duplex_m88()
1302 e_dbg("Waiting for forced speed/duplex link on M88 phy.\n"); in e1000e_phy_force_speed_duplex_m88()
1311 e_dbg("Link taking longer than expected.\n"); in e1000e_phy_force_speed_duplex_m88()
1399 e_dbg("IFE PMC: %X\n", data); in e1000_phy_force_speed_duplex_ife()
1404 e_dbg("Waiting for forced speed/duplex link on IFE phy.\n"); in e1000_phy_force_speed_duplex_ife()
1412 e_dbg("Link taking longer than expected.\n"); in e1000_phy_force_speed_duplex_ife()
1459 e_dbg("Half Duplex\n"); in e1000e_phy_force_speed_duplex_setup()
1463 e_dbg("Full Duplex\n"); in e1000e_phy_force_speed_duplex_setup()
1471 e_dbg("Forcing 100mb\n"); in e1000e_phy_force_speed_duplex_setup()
1475 e_dbg("Forcing 10mb\n"); in e1000e_phy_force_speed_duplex_setup()
1905 e_dbg("Phy info is only valid for copper media\n"); in e1000e_get_phy_info_m88()
1914 e_dbg("Phy info is only valid if link is up\n"); in e1000e_get_phy_info_m88()
1980 e_dbg("Phy info is only valid if link is up\n"); in e1000e_get_phy_info_igp()
2038 e_dbg("Phy info is only valid if link is up\n"); in e1000_get_phy_info_ife()
2161 e_dbg("Running IGP 3 PHY init script\n"); in e1000e_phy_init_script_igp3()
2565 e_dbg("Could not set Port Control page\n"); in e1000_enable_phy_wakeup_reg_access_bm()
2571 e_dbg("Could not read PHY register %d.%d\n", in e1000_enable_phy_wakeup_reg_access_bm()
2585 e_dbg("Could not write PHY register %d.%d\n", in e1000_enable_phy_wakeup_reg_access_bm()
2614 e_dbg("Could not set Port Control page\n"); in e1000_disable_phy_wakeup_reg_access_bm()
2621 e_dbg("Could not restore PHY register %d.%d\n", in e1000_disable_phy_wakeup_reg_access_bm()
2663 e_dbg("Attempting to access page %d while gig enabled.\n", in e1000_access_phy_wakeup_reg_bm()
2670 e_dbg("Could not enable PHY wakeup reg access\n"); in e1000_access_phy_wakeup_reg_bm()
2675 e_dbg("Accessing PHY page %d reg 0x%x\n", page, reg); in e1000_access_phy_wakeup_reg_bm()
2680 e_dbg("Could not write address opcode to page %d\n", page); in e1000_access_phy_wakeup_reg_bm()
2695 e_dbg("Could not access PHY reg %d.%d\n", page, reg); in e1000_access_phy_wakeup_reg_bm()
2796 e_dbg("reading PHY page %d (or 0x%x shifted) reg 0x%x\n", page, in __e1000_read_phy_reg_hv()
2919 e_dbg("writing PHY page %d (or 0x%x shifted) reg 0x%x\n", page, in __e1000_write_phy_reg_hv()
3018 e_dbg("Could not write the Address Offset port register\n"); in e1000_access_phy_debug_regs_hv()
3029 e_dbg("Could not access the Data port register\n"); in e1000_access_phy_debug_regs_hv()
3132 e_dbg("Waiting for forced speed/duplex link on 82577 phy\n"); in e1000_phy_force_speed_duplex_82577()
3140 e_dbg("Link taking longer than expected.\n"); in e1000_phy_force_speed_duplex_82577()
3171 e_dbg("Phy info is only valid if link is up\n"); in e1000_get_phy_info_82577()