Lines Matching refs:destination

36 neutral position leaving the signal unchanged. Note that if the  same destination 
268 This control specifies the destination - FX-bus accumulators. There are
271 0 - mono, A destination (FX-bus 0-15), default 0
272 1 - mono, B destination (FX-bus 0-15), default 1
273 2 - mono, C destination (FX-bus 0-15), default 2
274 3 - mono, D destination (FX-bus 0-15), default 3
275 4 - left, A destination (FX-bus 0-15), default 0
276 5 - left, B destination (FX-bus 0-15), default 1
277 6 - left, C destination (FX-bus 0-15), default 2
278 7 - left, D destination (FX-bus 0-15), default 3
279 8 - right, A destination (FX-bus 0-15), default 0
280 9 - right, B destination (FX-bus 0-15), default 1
281 10 - right, C destination (FX-bus 0-15), default 2
282 11 - right, D destination (FX-bus 0-15), default 3
289 It specifies the attenuation (amount) for given destination in range 0-255.
292 0 - mono, A destination attn, default 255 (no attenuation)
293 1 - mono, B destination attn, default 255 (no attenuation)
294 2 - mono, C destination attn, default 0 (mute)
295 3 - mono, D destination attn, default 0 (mute)
296 4 - left, A destination attn, default 255 (no attenuation)
297 5 - left, B destination attn, default 0 (mute)
298 6 - left, C destination attn, default 0 (mute)
299 7 - left, D destination attn, default 0 (mute)
300 8 - right, A destination attn, default 0 (mute)
301 9 - right, B destination attn, default 255 (no attenuation)
302 10 - right, C destination attn, default 0 (mute)
303 11 - right, D destination attn, default 0 (mute)