Lines Matching refs:temperature
38 (automatic fan speed control) on all temperature/PWM combinations, 2
52 - If the value is 6, it starts monitoring using the temperature sensor
60 For temperature sensors, an alarm triggers if the measured value goes
61 above the high temperature limit, and wears off only after the measured
73 Each temperature channel can control all the 8 PWM outputs (by setting the
74 corresponding bit in tempX_fan_map), you can set the temperature channel
78 PWM value requests from different temperature channels, but the chip
81 In Thermal Cruise mode, the chip attempts to keep the temperature at a
85 the PWM value. If the temperature is within the tolerance range, the PWM
88 SmartFanII works differently, you have to define up to 7 PWM, temperature
89 trip points, defining a PWM/temperature curve which the chip will follow.