Lines Matching refs:temperature
38 The driver implements three temperature sensors, seven fan rotation speed
47 the temperature gets higher than the Overtemperature Shutdown value; it stays
48 on until the temperature falls below the Hysteresis value.
88 Tart will be asserted while target temperature cannot be achieved after 3 minutes
128 range. At first a wanted temperature and interval must be set. This is done
130 interval. The fan speed will be lowered as long as the current temperature
131 remains below the thermal_cruise# +- tolerance# value. Once the temperature
134 with the temperature varying. Three conditions may occur:
136 (1) If the temperature still exceeds the high limit, PWM duty
139 (2) If the temperature goes below the high limit, but still above the low
141 the temperature is in the target range.
143 (3) If the temperature goes below the low limit, PWM duty cycle will decrease
144 slowly to 0 or a preset stop value until the temperature exceeds the low
150 W83792D also provides a special mode for fan. Four temperature points are
151 available. When related temperature sensors detects the temperature in preset
152 temperature region (sf2_point@_fan# +- tolerance#) it will cause fans to run
162 pwm[1-3]_enable - this file controls mode of fan/temperature control:
170 thermal_cruise[1-3] - Selects the desired temperature for cruise (degC)
172 sf2_point[1-4]_fan[1-3] - four temperature points for each fan for Smart Fan II