Lines Matching refs:From
20 From datasheets:
72 in[1-12]_input Measured voltage. From READ_VOUT register.
73 in[1-12]_min Minimum Voltage. From VOUT_UV_WARN_LIMIT register.
74 in[1-12]_max Maximum voltage. From VOUT_OV_WARN_LIMIT register.
76 in[1-12]_crit Critical maximum voltage. From VOUT_OV_FAULT_LIMIT register.
77 in[1-12]_min_alarm Voltage low alarm. From VOLTAGE_UV_WARNING status.
78 in[1-12]_max_alarm Voltage high alarm. From VOLTAGE_OV_WARNING status.
79 in[1-12]_lcrit_alarm Voltage critical low alarm. From VOLTAGE_UV_FAULT status.
80 in[1-12]_crit_alarm Voltage critical high alarm. From VOLTAGE_OV_FAULT status.
83 curr[1-12]_input Measured current. From READ_IOUT register.
84 curr[1-12]_max Maximum current. From IOUT_OC_WARN_LIMIT register.
85 curr[1-12]_lcrit Critical minimum output current. From IOUT_UC_FAULT_LIMIT
87 curr[1-12]_crit Critical maximum current. From IOUT_OC_FAULT_LIMIT register.
88 curr[1-12]_max_alarm Current high alarm. From IOUT_OC_WARNING status.
89 curr[1-12]_crit_alarm Current critical high alarm. From IOUT_OC_FAULT status.
95 temp[1-2]_input Measured temperatures. From READ_TEMPERATURE_1 and
97 temp[1-2]_max Maximum temperature. From OT_WARN_LIMIT register.
98 temp[1-2]_crit Critical high temperature. From OT_FAULT_LIMIT register.