43 in[1-2]_input Measured voltage. From READ_VOUT register.
46 curr[1-2]_input Measured current. From READ_IOUT register.
48 curr1_max Maximum current. From IOUT_OC_WARN_LIMIT register.
49 curr1_crit Critical maximum current. From IOUT_OC_FAULT_LIMIT register.
50 curr1_max_alarm Current high alarm. From IOUT_OC_WARN_LIMIT status.
51 curr1_crit_alarm Current critical high alarm. From IOUT_OC_FAULT status.
52 curr2_alarm Current high alarm. From IOUT_OC_WARNING status.
54 temp1_input Measured temperature. From READ_TEMPERATURE_2 register on page 0.
55 temp1_max Maximum temperature. From OT_WARN_LIMIT register.
56 temp1_crit Critical high temperature. From OT_FAULT_LIMIT register.
63 temp2_input Measured temperature. From READ_TEMPERATURE_2 register on page 1.