Lines Matching refs:From
44 in1_input Measured voltage. From READ_VOUT register.
45 in1_min Minimum Voltage. From VOUT_UV_WARN_LIMIT register.
46 in1_max Maximum voltage. From VOUT_OV_WARN_LIMIT register.
48 in1_crit Critical maximum voltage. From VOUT_OV_FAULT_LIMIT register.
49 in1_min_alarm Voltage low alarm. From VOLTAGE_UV_WARNING status.
50 in1_max_alarm Voltage high alarm. From VOLTAGE_OV_WARNING status.
51 in1_lcrit_alarm Voltage critical low alarm. From VOLTAGE_UV_FAULT status.
52 in1_crit_alarm Voltage critical high alarm. From VOLTAGE_OV_FAULT status.
57 curr1_input Measured current. From READ_IOUT register.
58 curr1_max Maximum current. From IOUT_OC_WARN_LIMIT register.
59 curr1_crit Critical maximum current. From IOUT_OC_FAULT_LIMIT register.
60 curr1_max_alarm Current high alarm. From IOUT_OC_WARN_LIMIT register.
61 curr1_crit_alarm Current critical high alarm. From IOUT_OC_FAULT status.
65 temp1_input Measured temperature. From READ_TEMPERATURE_1 register.
66 temp1_max Maximum temperature. From OT_WARN_LIMIT register.
67 temp1_crit Critical high temperature. From OT_FAULT_LIMIT register.