Lines Matching refs:From
75 in[1-6]_input Measured voltage. From READ_VOUT register.
76 in[1-6]_min Minimum Voltage. From VOUT_UV_WARN_LIMIT register.
77 in[1-6]_max Maximum voltage. From VOUT_OV_WARN_LIMIT register.
79 in[1-6]_crit Critical maximum voltage. From VOUT_OV_FAULT_LIMIT register.
80 in[1-6]_min_alarm Voltage low alarm. From VOLTAGE_UV_WARNING status.
81 in[1-6]_max_alarm Voltage high alarm. From VOLTAGE_OV_WARNING status.
82 in[1-6]_lcrit_alarm Voltage critical low alarm. From VOLTAGE_UV_FAULT status.
83 in[1-6]_crit_alarm Voltage critical high alarm. From VOLTAGE_OV_FAULT status.
91 curr[1-6]_input Measured current. From READ_IOUT register.
92 curr[1-6]_max Maximum current. From IOUT_OC_WARN_LIMIT register.
93 curr[1-6]_crit Critical maximum current. From IOUT_OC_FAULT_LIMIT register.
94 curr[1-6]_max_alarm Current high alarm. From IOUT_OC_WARNING status.
95 curr[1-6]_crit_alarm Current critical high alarm. From IOUT_OC_FAULT status.
110 temp[1-8]_input Measured temperatures. From READ_TEMPERATURE_1 register.
115 temp[1-8]_max Maximum temperature. From OT_WARN_LIMIT register.
116 temp[1-8]_crit Critical high temperature. From OT_FAULT_LIMIT register.