65 Remote 1 is generally the CPU temperature. These inputs are designed to
67 423 or socket 478 package. They can also measure temperature using a
72 three temperature sensors. Each PWM output is individually adjustable and
77 Each of the measured inputs (voltage, temperature, fan speed) has
98 To smooth the response of fans to changes in temperature, the LM85 has an
104 to the temperature readings that is automatically applied during
134 of voltage and temperature channels.
152 temperature sensors fail. Individual sensor interrupts can be masked so
159 control dynamic Tmin feature can be enabled to keep the system temperature
169 Each temperature sensor is associated with a Zone. There are three
171 temperature configuration points:
173 * temp#_auto_temp_off - temperature below which fans should be off or spinning very low.
174 * temp#_auto_temp_min - temperature over which fans start to spin.
175 * temp#_auto_temp_max - temperature when fans spin at full speed.
176 * temp#_auto_temp_crit - temperature when all fans will run full speed.
186 temperature. (PWM value from 0 to 255)
188 * pwm#_auto_pwm_minctl - this flags selects for temp#_auto_temp_off temperature
228 adjust the Tmin value to maintain the measured temperature sensor at a
229 specified temperature. There isn't much documentation on this feature in