Lines Matching refs:zone
165 be retrieved via the zone[1-3]_auto_channels_temp attributes. Each PWM output
166 is assigned to one (or hottest of multiple) temperature zone(s) through the
171 programmed via zone[1-3]_auto_point[1-3]_temp and
172 zone[1-3]_auto_point1_temp_hyst:
178 zone[1-3]_auto_point3_temp full-speed temp (all outputs)
179 zone[1-3]_auto_point2_temp full-speed temp
180 zone[1-3]_auto_point1_temp low-speed temp
181 zone[1-3]_auto_point1_temp_hyst min-speed temp
184 to auto_point2_pwm if the temperature of the associated zone is between
193 based on the temperature of the associated thermal zone:
242 zone[1-3]_auto_channels_temp RO Temperature zone to temperature input
248 zone[1-3]_auto_point1_temp_hyst RW Auto PWM temp point1 hysteresis. The
253 zone[1-3]_auto_point[1-3]_temp RW Auto PWM temp points. Auto_point1 is
294 pwm[1-3]_auto_channels_zone RW PWM output to temperature zone mapping.
300 6: highest of zone[2-3]
301 7: highest of zone[1-3]
319 zone[1-3]_hyst yes yes