Lines Matching refs:fan
27 The fan speed control uses this finer value to produce a "step-less" fan
37 data sheet. Our temperature reports and fan PWM outputs are very smooth
50 Since there is a fan to zone assignment that allows for the "hotter" of
51 a set of zones to control the PWM of an individual fan, but there is no
53 is currently controlling the PWM for a given fan. This is in register
65 individual fans on each that would benefit from individual fan control.
69 fan types. We can also support pulse-stretched PWM so that 3-wire fans
84 Using temperature information from these four zones, an automatic fan speed
88 To set fan speed, the aSC7621 has three independent pulse width modulation
93 temperature readings for better control of fan speed and minimum acoustic
96 The aSC7621 has tachometer inputs to measure fan speed on up to four fans.
109 - Programmable autonomous fan control based on temperature readings
110 - Noise filtering of temperature reading for fan speed control
112 - 3 PWM fan speed control outputs for 2-, 3- or 4-wire fans and up to 4 fan
222 i.e. when pwm = 0, the fan will be on full and
223 when pwm = 255 the fan will be off.