smartctl 7.1 2019-12-30 r5022 [x86_64-linux-5.4.0-135-generic] (local build)
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     HS-SSD-WAVE(S) 256G
Serial Number:    30107737268
LU WWN Device Id: 5 000000 0000027b6
Firmware Version: HS14825
User Capacity:    256,060,514,304 bytes [256 GB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    Solid State Device
Form Factor:      2.5 inches
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   ACS-4 (minor revision not indicated)
SATA Version is:  SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is:    Mon Sep 18 17:14:42 2023 JST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00)	Offline data collection activity
					was never started.
					Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0)	The previous self-test routine completed
					without error or no self-test has ever 
					been run.
Total time to complete Offline 
data collection: 		(   33) seconds.
Offline data collection
capabilities: 			 (0x7b) SMART execute Offline immediate.
					Auto Offline data collection on/off support.
					Suspend Offline collection upon new
					command.
					Offline surface scan supported.
					Self-test supported.
					Conveyance Self-test supported.
					Selective Self-test supported.
SMART capabilities:            (0x0003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					General Purpose Logging supported.
Short self-test routine 
recommended polling time: 	 (   2) minutes.
Extended self-test routine
recommended polling time: 	 (  85) minutes.
Conveyance self-test routine
recommended polling time: 	 (   2) minutes.
SCT capabilities: 	       (0x0031)	SCT Status supported.
					SCT Feature Control supported.
					SCT Data Table supported.

SMART Attributes Data Structure revision number: 20
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  5 Reallocated_Sector_Ct   0x0013   100   100   050    Pre-fail  Always       -       0
  9 Power_On_Hours          0x0012   100   100   000    Old_age   Always       -       4
 12 Power_Cycle_Count       0x0012   100   100   000    Old_age   Always       -       2
167 Unknown_Attribute       0x0022   100   100   000    Old_age   Always       -       0
168 Unknown_Attribute       0x0012   100   100   000    Old_age   Always       -       0
169 Unknown_Attribute       0x0013   100   100   010    Pre-fail  Always       -       327690
170 Unknown_Attribute       0x0033   100   100   010    Pre-fail  Always       -       100
171 Unknown_Attribute       0x0032   100   100   000    Old_age   Always       -       0
172 Unknown_Attribute       0x0032   100   100   000    Old_age   Always       -       0
174 Unknown_Attribute       0x0022   100   100   000    Old_age   Always       -       0
175 Program_Fail_Count_Chip 0x0022   100   100   010    Old_age   Always       -       0
177 Wear_Leveling_Count     0x0012   100   100   000    Old_age   Always       -       0
180 Unused_Rsvd_Blk_Cnt_Tot 0x0033   100   100   000    Pre-fail  Always       -       25
183 Runtime_Bad_Block       0x0033   100   100   000    Pre-fail  Always       -       0
184 End-to-End_Error        0x003b   100   100   090    Pre-fail  Always       -       0
192 Power-Off_Retract_Count 0x0012   100   100   000    Old_age   Always       -       2
194 Temperature_Celsius     0x0022   034   034   000    Old_age   Always       -       34 (Min/Max 28/34)
196 Reallocated_Event_Count 0x0012   100   100   000    Old_age   Always       -       0
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       -       0
199 UDMA_CRC_Error_Count    0x0032   100   100   000    Old_age   Always       -       0
206 Unknown_SSD_Attribute   0x0032   200   200   000    Old_age   Always       -       3
207 Unknown_SSD_Attribute   0x0032   200   200   000    Old_age   Always       -       44
208 Unknown_SSD_Attribute   0x0032   200   200   000    Old_age   Always       -       11
231 Temperature_Celsius     0x0023   100   100   005    Pre-fail  Always       -       0
233 Media_Wearout_Indicator 0x0032   100   100   000    Old_age   Always       -       913
234 Unknown_Attribute       0x0032   100   100   000    Old_age   Always       -       252278
241 Total_LBAs_Written      0x0032   100   100   000    Old_age   Always       -       426
242 Total_LBAs_Read         0x0032   100   100   000    Old_age   Always       -       199

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.