180105-180021 root@catbox:/home/furuta# smartctl -a ./dev/sdb smartctl 6.2 2013-07-26 r3841 [x86_64-linux-3.13.0-85-generic] (local build) Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Western Digital Scorpio Blue Serial ATA Device Model: WDC WD5000BEVT-22ZAT0 Serial Number: WD-WX60A99V8274 LU WWN Device Id: 5 0014ee 258ce1b5b Firmware Version: 01.01A01 User Capacity: 500,107,862,016 bytes [500 GB] Sector Size: 512 bytes logical/physical Rotation Rate: 5400 rpm Device is: In smartctl database [for details use: -P show] ATA Version is: ATA8-ACS (minor revision not indicated) SATA Version is: SATA 2.6, 3.0 Gb/s Local Time is: Fri Jan 5 20:08:27 2018 JST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00)Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0)The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (12780) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003)Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01)Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 149) minutes. Conveyance self-test routine recommended polling time: ( 5) minutes. SCT capabilities: (0x303f)SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 70 3 Spin_Up_Time 0x0027 181 176 021 Pre-fail Always - 1941 4 Start_Stop_Count 0x0032 099 099 000 Old_age Always - 1240 5 Reallocated_Sector_Ct 0x0033 199 199 140 Pre-fail Always - 4 7 Seek_Error_Rate 0x002e 200 200 000 Old_age Always - 0 9 Power_On_Hours 0x0032 042 042 000 Old_age Always - 42637 10 Spin_Retry_Count 0x0033 100 100 051 Pre-fail Always - 0 11 Calibration_Retry_Count 0x0032 100 100 000 Old_age Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 166 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 89 193 Load_Cycle_Count 0x0032 015 015 000 Old_age Always - 556130 194 Temperature_Celsius 0x0022 123 093 000 Old_age Always - 24 196 Reallocated_Event_Count 0x0032 199 197 000 Old_age Always - 1 197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0030 100 253 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x0009 100 253 051 Pre-fail Offline - 0 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. 180105-200827 root@catbox:/home/furuta#